Installation manual

Windsor 500 Installation Manual - Issue C
-
-
System Components
Technical Specification
Electrical
Mains Input 230V AC (+10% -15%) 50/60 Hz
Mains fail detection Loss of AC supply
Power supply voltage Normally +13.7V
Low voltage detection 11V DC
Power fail detection 10.7V DC
Power supply output 2 amps
Load current 500 mA to ensure 8 hours standby 6 Ah
Load current 1 amp to ensure 8 Hours standby 15 Ah
Standby battery 6 Ah, 15 Ah or 2x 6 Ah lead acid rechargeable
Environmental
Temperature range -10 to 50 °C (0° - 40° for control panel)
Humidity 10% to 90% relative humidity
Dimensions
Control panel 335 x 455 x 116 (W x H x D) mm (Windsor Mk 1)
Control panel 365 x 445 x 110 (W x H x D) mm (Windsor 500)
Keypad 155 x 105 x 25 (W X H X D) mm
Keypoint 90 x 90 x 25 (W X H X D) mm
External Concentrator 125 x 215 x 50 (W X H X D) mm
Packed Weights (Approximate)
Control panel assembly 8.5 kg
Keypad 0.35 kg
Keypoint 0.25 kg
External Concentrator 0.35 kg
System Components
Cable Type
Windsor has two 4 wire buses, one for the user interfaces and one for the concentrators. The
recommended cable type is 7 strand/0.2mm
2
diameter un-screened cable which has a
resistance of 90 ohms/km and a core to core capacitance of 100nF/km. The screened cable
referred to in this manual has the same resistance as un-screened cable but has a higher
capacitance of 250nF/km between any core and the screen. If screened cable is used it
should be terminated in the Windsor control panel and connected to earth. Refer to the
section on user interfaces and concentrators for details of the maximum length of cable on
each bus.