Service manual
Section 8A
8A-22 
37. Purge the hydraulic system of air by operating all 
boom functions through their entire range of motion 
several times. Check the hydraulic oil level.
38. Check for proper operation of all components.
39. Turn the engine OFF.
8A.10 PERKINS ENGINE STORAGE
If the engine is properly protected and stored according 
to the following recommendations, no corrosion damage 
will normally occur. Perkins Engine Company, Inc. and 
Sky Trak International are not responsible for any dam-
age that occurs in relation to a service storage period.
Use the following procedures immediately upon remov-
ing engine from service if being stored for an extended 
period of time.
1. Clean the outside of the engine.
2. When using a preservative fuel, drain the fuel system 
and fill with the preservative fuel. When not using 
preservative fuel, keep the fuel system charged with 
regular fuel, which, along with the fuel filter, will have 
to be drained and discarded at the end of the storage 
period.
3. Run the engine to operating temperature. Correct 
any fuel, fluid, oil or air leaks. Stop the engine and 
drain the oil.
4. Replace the oil filter.
5. Fill the crankcase (sump) to the FULL mark on the 
dipstick with new, clean oil or with an approved 
preservative fluid. If a preservative fluid is used, it 
must be drained and replaced with regular lubricating 
oil before the engine is returned to service.
6. Drain the cooling system. To provide protection 
against corrosion, fill the cooling system with a 
coolant containing a corrosion inhibitor. If frost 
protection is needed, use the appropriate mixture of 
antifreeze and water. If frost protection is not 
required, use an appropriate mixture of water with an 
approved corrosion mixture.
7. Run the engine for a short period to distribute 
lubricating oil and coolant throughout the engine.
8. Clean out the engine breather pipe (where fitted) and 
seal the end of the pipe.
9. Remove the fuel injectors and spray clean engine 
lubricating oil into cylinder bores, four ounces (118,3 
ml) of lubricating oil divided evenly between the four 
cylinders.
10. Remove the air filter and any pipe installed between 
the air filter and the induction manifold. Seal the 
manifold with waterproof tape.
11. Remove the exhaust pipe. Seal the manifold with 
waterproof tape.
12. Disconnect the battery and store it safely, in a fully 
charged condition. Before the battery is put into 
storage, give the battery terminals a protection 
against corrosion with a light coating of dielectric 
grease or petroleum jelly.
13. Seal the vent pipe of the fuel tank or the fuel filler cap 
with waterproof tape.
14. Remove and store the fan drive belt.
Note: Before starting the engine after storage, operate 
the starter motor with one of the fuel-run solenoid wires 
disconnected until oil pressure shows on the oil pressure 
gauge, or until the low oil-pressure warning light goes 
out.
Model 3606 • Origin 10/99