Instruction manual

1070 072 163-101 (97.11) GB
BT5 Menu Description 7-5
7.3.2 Criteria Display
While in Cascade Status, pressing the [print] key accesses the Criteria
Analysis (mask number 11).
K1S 1
16.06.95
A F AutD
9:45:15
UN E 00
.
.2 Z2 n.vor
UN E 14.4 Z3 n.vor
Fig. 7-5 Example of Criteria Display
Designations for inputs and markers (criteria text) must be entered in the
TS (TesiMod) software. The appropriate level / location is reached by us-
ing the following sequence of menu commands:
Edit /Masks file / Edit /Edit text lists /Select text list.
At the location thus reached, and building on a base code, criteria text di-
agnostics can then be entered in the form of decimal values.
Operand Base Code
Inputs I 1000
Outputs O 3000
Markers M 4000
Special markers Sm 7000
Timers T 8000
Counters C 9000
Fig. 7-6 Operand Base Codes
Example: Input I0.2 (base code + byte address + bit address)
Base code 1000 = I0.0, base code 1001 = I0.1, etc.
Therefore, in the example shown in the screen mask in Fig. 6-5, above,
the following will apply:
for I0.2 = Z2 n. vor (fwd.) -> Enter: 1002 = C2 n vor (fwd.)
Display Contents
Cascade number and active step
System date and time of first-value message occurrence
OpMode:
H Manual mode
T Inching mode
A Automatic
Cascade status:
F Cascade faulty
Automatic or Manual diagnostics
Criteria status:
Conditions not met
Conditions met
Criteria text, up to 8 characters in length.