DM255 / 254 / 120 Data Modules 6-3
No. Symbol Explanation Data format
Entry made by:
B: BTSMADAP
A: User
D448 STEU_FRG Control enabled if contents =1 (0: "control
disabled")
hex A
INTERNAL PLC MESSAGES B
D450 Battvorw hex B
D452 Ages/Fix hex B
D454 Watchdog decimal B
D456 Zykl_max decimal B
D458 Zykl_akt decimal B
READ/WRITE AREAS OF BT5 / BT20 TERMINALS B
16 (bytes) x 8 status messages (parallel) B
D460 BT_ZM Bosch-internal status messages no. 1 thru 16 binary B
D462 User status messages, no's. 17 thru 32 binary B
D464 User status messages, no's. 33 thru 48 binary B
D466 User status messages, no's. 49 thru 64 binary B
D468 User status messages, no's. 65 thru 80 binary B
D470 User status messages, no's. 81 thru 96 binary B
D472 User status messages, no's. 97 thru 112 binary B
D474 User status messages, no's. 113 thru 128 binary B
D476 hex B
D478 BT5? BT5 Application
hex
User
D480 BT_Uhr BT clock, 8 bytes hex B
D482 hex B
D484 hex B
D486 hex B
D488 BT_MskNr Screen number decimal B
D490 BT_DIP DIP switch binary B
D492 BT_KO Write coordination byte binary B
8 bytes BT polling range B
D494 BT_Poll1 Read coordination byte, / ----- binary B
D496 BT_Poll2 Serial message channel hex B
D498 BT_Poll3 LED 1 thru 8, e.g. bit1=LED On/Off, bit0=flashes hex B
D500 BT_Poll4 LED 9 thru 16 hex B
Clear serial message buffer B
D502 BT_M_loe with code E216H + 7FFEh on serial message channel hex B
D504 BT_Tast Function key code for operator terminal hex B
Fig. 6-2 Allocation of Komm_DB Communication Module (DM255)
D478 of the data module defines which operator terminal is connected to
the PLC. With D478=5, a BT5, and with D478=0, a BT20 is declared. In
the event that this identifier is not entered during the operation of the BT5,
the movement function keys (F1, F2, F5, and F6) will be disabled. In the
case of the CL400 / CL500 controllers, the same condition will prevent the
synchronization result (LED in the respective movement keys) to be dis-
played.