BTSMADAP & BTS_ZV Function Modules 5-3
5.3 BTSMADAP Function Module for CL400 / CL500
5.3.1 Prerequisites and Allocations
Hardware:
BT5, variant HF000040 and up
BT20, variant HB000400 and up
ZE400, version 1.2 and higher, front panel 1
SK500, version 102 and higher, front panel 2
with ZS500, version 104 and higher, type 3 front panel, OR
with ZS501, version 103 and higher, type 2 front panel, OR
with ZS510, version 301 and higher, type 1 front panel
Software:
TesiMod, version 4.0 and higher
DIAG500E, version 2.1 and higher
KETTE, version 2.1 and higher
Allocations:
Counter: C0
Scratch markers: M230 through M254
BT Markers: M178 through M188
5.3.2 Description of Parameters
CM -BTSMADAP,3
; +---+
P0 W -Kett_Anz ; < ! Number corresponds to the last cascade number
P1 W -K180 ; < ! Start addr. in oper. screen, delete "-"
P2 W -DIAG500E ; < ! Diagnostics module
; +---+
Fig. 5-2 Call-up of BTSMADAP Function Module for CL400 / CL500
P0 -Kett_Anz
At this point, the number of the last cascade sequence is entered in the
form of a decimal constant. Gaps in the chronological sequence of cas-
cade sequence numbers are permitted.
Example: Cascade sequences 1 through 5, 7, and 10 through 15 are
available. Therefore, parameter P0 is structured as follows:
• P0 word K15
P1 K180 (delete "-" symbol)