BTSMADAP & BTS_ZV Function Modules 5-1
5 BTSMADAP & BTS_ZV Function Modules
5.1 BTSMADAP Function Module
The BTSMADAP function module prepares the data from the program-
mable logic controller (PLC) for the operator terminal, and transfers re-
quests issued by the operator terminal to the PLC. The relevant
parameterization is almost identical for all controller variants
3
. In the case
of the CL200, the respective module number for the KETTE200 function
module must be taken from the symbol file and transferred to parameter
P1 in the form of a decimal constant. This results in the subsequent mod-
ule calls discussed in 4.2 and 4.3, below, that can be loaded into the
module editor by means of the Load Parameter List function of the pro-
gramming device.
5.1.1 Module Functions
The BTSMADAP module
• controls the manual operation,
• calls up the diagnostic module,
• prepares the diagnostic data stored in DM120 for display on the
operator terminal,
and
• controls the status display,
as well as the
• status messages.
In order to handle the described tasks, the BTSMADAP module requires
two data modules — one for processing the diagnostic data, and the other
for general communications between operator terminal and PLC.
3
Applies to CL200 with BTSMADAP, version 1.1 and higher.