Instruction manual
1070 072 163-101 (97.11) GB
CL350 / CL400 / CL500 Control Functions 4-19
4.6 Cascade Data Module
The cascade data module managing the sequential control provides all
essential system control data.
Symbol Explanation Data format
Entry made by:
K: KETTE
B: BTSMADAP
A: User
D00 nnFehler Fault bits binary K
D02 nnKettNr Cascade number n (1 through 60) decimal K
D04 nnSchAnz Number of steps in cascade decimal K
D06 nnBaWahl OpMode selection binary K
D08 nnBaMldg Reported OpMode binary K
D10 nnSchr-1 Step number, preceding step decimal K
D12 nnSchr. Step number, current step decimal K
D14 nnSchr.S Step number, Set Step instruction decimal B
D16
D18 nn-KWA Actual value, wait time dec x 100 ms
K/A
D20 nn-KUE Actual value, monitoring time dec x 100 ms
K/A
D22 nnINT0 internal use
:: :: internal use
D28 nnINT3 internal use
D30 nnBa_Ext OpMode selection for external operator terminals binary K
D32 nnINT4 internal use
:: :: internal use
D46 nnSyn16 Synchronization step 1 through 16 binary K
:: :: :: K
D62 nnSyn128 Synchronization step 113 through 128 binary K
D64 nnSch16 Steps 1 through 16 binary K
:: :: :: K
D78 nnSch128 Steps 113 through 128 binary K
D80 nnBef16 Command output for steps 1 thru 16 binary K
:: :: :: K
D94 nnBef128 Command output for steps 113 thru 128 binary K
D100 nnK/S_1L HBy = Cascade no./ LBy = Step no.
to movement screen, line 1 left
hex A
:: :: as in D100, for movement left A
D106 nnK/S_4L HBy = Cascade no./ LBy = Step no.
to movement screen, line 4 left
hex A
:: :: as in D108 - D114, res'd for movement A
D116 nnK/S_1R HBy = Cascade no./ LBy = Step no.
to movement screen, line 1 right
hex A
:: :: as in D116, for movement right A
D122 nnK/S_4R HBy = Cascade no./ LBy = Step no.
to movement screen, line 4 right
hex A
:: :: as in D124 - D130, res'd for movement A
Fig. 4-10 CL400 / CL500 Cascade Data Module