Instruction manual

1070 072 163-101 (97.11) GB
CL350 / CL400 / CL500 Control Functions4-18
-Schritt2
A B I0.2
= B -BEFA
A B I0.3
= B -WSB ; Mandatory requirement
EM ; for end of step.
Fig. 4-9 Step Module for CL400 / CL500
In the event that a given step has identical Manual and Automatic mode
movements, the selection of the operating mode can be omitted (as in
step 2).
4.5.1 Diagnostics
The machine is monitored by the DIAG500E module.
The presence of scratch markers in steps can lead to undefinable diag-
nostic results (e.g. the wait time also comprises a scratch marker).