CL350 / CL400 / CL500 Control Functions 4-11
D6.4 S+1
Execute the subsequent step.
In INCHING mode, a positive transition of this bit and satisfied step-on
condition (WSB = 1
bin
) will cause the next step to be executed.
In SEMI-AUTOMATIC mode, a positive transition of this bit, satisfied step-
on condition (WSB = 1
bin
), and with -HALBAUTO marker set, cause the
subsequent cascade sequence to be processed up to the reset -
HALBAUTO marker.
D6.5 Set Step
Accept preselected step number.
In MANUAL mode, the step prepared in D14 is transferred to the active
step (D12), and subsequently processed.
D6.6 Halt Acknowledgement
Manual fault acknowledgement.
Effective only if D7.7 = 1
bin
(manual fault acknowledgement).
A positive transition on this bit acknowledges a fault (cascade halted) that
was triggered by an expired monitoring time or by the reset fault marker.
Monitoring and wait times are loaded with the defined values but not
started.
D6.7 Reset
Resetting the cascade
D6.7 = 1
bin
will initiate the following actions:
• Deletion of active step
• Reinitialization of cascade sequence
• Generates new cascade data module
Subsequent to Reset, step 1 is prepared.
D7.0 Halt
Stop cascade progress.
If this bit is set, the cascade is stopped, and the current step continues to
be processed. For D7.0 = 1
bin
, the following applies:
• BEFA is output
• monitoring time is halted
• wait time is halted