CL350 / CL400 / CL500 Control Functions4-10
4.4.5 D6 — Selected Operating Mode
Further to the operating modes discussed in the preceding sections, the
D6 data word in the cascade data module contains additional information
relative to operating modes.
D6 nnBaWahl
This data word is written to by the KETTE cascade management module
via parameter P1 (-BETR).
D6.0 Manual mode H
D6.1 Inching mode T
D6.2 Automatic mode
A
D6.3 Start s
D6.4 S + 1
D6.5 Set Step
D6.6 Fault acknowledgement
D6.7 Reset
r
D7.0 Halt h
D7.1
D7.2
D7.3
D7.4
D7.5
D7.6 WSB does not reset BEFA (Manual only)
D7.7 Fault requires acknowledgement
Fig. 4-6 D6 — Selected Operating Mode
D6.0 Manual Mode
Define Manual mode.
D6.1 Inching Mode
Define Inching mode.
D6.2 Automatic Mode
Define Automatic mode.
D6.3 Start
Start / Command output enable
The bit is valid for all operating modes, and is statically transferred to pa-
rameter P1 of the KETTE cascade management module.
If Start = 0
bin
, the following will occur:
• BEFA is deleted
• monitoring time is halted
• wait time continues to elapse
To generate the cascade data modules, and to effect synchronization in
Automatic mode, the Start instruction must be deleted.