Instruction manual

1070 072 163-101 (97.11) GB
CL350 / CL400 / CL500 Control Functions 4-7
4.4.2 Inching Mode / Single Step
Function
Step-by-step processing of steps in accordance with conditions of the
automatic branch.
The command output is enabled when
the conditions of the automatic branch have been met, (BEFA =
1
bin
, and WSB = 0
bin
), and
when the Start (D6.3 ) = 1
bin
.
The command output occurs via the data bits of data words D80 through
D94 of the associated cascade data module (see cascade data module).
No step-on is enabled.
In the case of a positive transition on S+1 (D6.4), if WSB step-on condi-
tions are met, the step-on to the next step will occur.
Programming
The Inching bit is to be statically set to 1
bin
. Start = 1
bin
causes the current
step to be processed, and a positive transition on S+1 causes the step-on
into the subsequent step.
Diagnostics
Display in cascade information indicates T (indicating incremental ad-
vance by Touch control) for Inching mode at the corresponding cascade
sequence.
Display of all criteria of the automatic branch, either of the non-executed
BEFA or of the WSB branch.
The faulty cascade sequence is displayed.
Monitoring and wait time elapse with the default nominal values.