Instruction manual

1070 072 163-101 (97.11) GB
CL350 / CL400 / CL500 Control Functions4-2
4.2.2 Markers
Within the range of available markers, the markers listed below are as-
signed a permanent function.
Symbol Address Function
CL400/CL500
BEFA M255.0 Assigned to command output.
WSB M255.1 Assigned to step-on function.
STOEM M255.2 Fault marker; fault is indicated by STOEM = 0
bin
HALBAUTO M255.4 Step-on in Inching mode also without S+1 transition.
WZT_HLT M255.5 Wait time stop.
WZT M255.6 Wait time status 0
bin
: Wait time running
1
bin
: Wait time expired
UEKONTR M255.7 Monitoring time check
If UEKONTR = 1
bin
, expiration of monitoring time will not trigger diagnostic func-
tion.
VERZW M242 Branching address (word)
Step number within the cascade to which branching is to take place if WSB = 1
bin
.
Fig. 4-1 CL400 / CL500 Control Functions, Marker Definitions