Instruction manual
1070 072 163-101 (97.11) GB
CL350 / CL400 / CL500 Control Functions 4-1
4 CL350 / CL400 / CL500 Control Functions
4.1 Introduction
Chapter 3 discusses the control sequence management, including the
different operating modes it provides, plus process organization and
command output functions. Function modules are available to handle the
sequential control, diagnostic functions and display processes.
4.2 Definitions
To ensure orderly sequential processing and/or ascertain the production
of unambiguous diagnostic values, the use of the BT-MADAP software
package shall be governed by the definitions and conventions outlined
below.
4.2.1 Modules
The KETTE function module manages a maximum of
• 60 control sequences,
• containing 128 steps each,
• with one active step per each cycle.
The following modules are permanently assigned to the above control se-
quences:
• Function modules PM1 - PM60 (control sequences)
• Data modules DM1 - DM60 (cascade data modules)
Here the PM and DM numbers correspond to the cascade numbers.
Data storage and transfer is handled by the DM120 data module.