Instruction manual

1070 072 163-101 (97.11) GB
CL200 Control Functions3-20
3.6 Cascade Data Module
The cascade data module managing the sequential control provides all
essential system control data.
Symbol Explanation Data format
Entry made by:
K: KETTE200
B: BTSMADAP
A: User
D00 nnFehler Fault bits binary K
D02 nnKettNr Cascade number n (1 thru 30) decimal A
D04 nnSchAnz Number of steps in cascade decimal A
D06 nnBaWahl OpMode selection binary A
D08 nnBaMldg Reported OpMode binary K
D10 nnSchr-1 Step number, preceding step decimal K
D12 nnSchr. Step number, current step decimal K
D14 nnSchr.S Step number, Set Step instruction decimal B
D16 nnBefaAus Step number for command output decimal K
D18 nn-KWA Actual value, wait time dec x 100ms
K/A
D20 nn-KUE Actual value, monitoring time dec x 100ms
K/A
D22 nn-SKWA Setpoint value, cascade wait time dec x 100ms A
D24 nn-SKUE Setpoint value, cascade monitoring time dec x 100ms A
D26 K
D28 K
D30 K
D32 nnK/S_1L HBy = Cascade no./ LBy = Step no.
to movement screen, line 1 left
hex A
:: :: as in D32, for movement left A
D38 nnK/S_4L HBy = Cascade no./ LBy = Step no.
to movement screen, line 4 left
hex A
:: :: as in D40 - D46, reserved for movement A
D48 nnK/S_1R HBy = Cascade no./ LBy = Step no.
to movement screen, line 1 right
hex A
:: :: as in D48, for movement right A
D54 nnK/S_4R HBy = Cascade no./ LBy = Step no.
to movement screen, line 4 right
hex A
:: :: as in D56 - D62, reserved for movement A
D64 internal occupied by KETTE200 K
:: :: :: K
D80 internal occupied by KETTE200 K
Fig. 3-10 CL200 Cascade Data Module
Movement Screen and Data Module Allocations:
Movement screen 211 -> DM1, D32
Movement screen 212 -> DM2, D32, and so forth.