CL200 Control Functions 3-11
3.4.5 D6 — Selected Operating Mode
Further to the operating modes discussed in the preceding sections, the
D6 data word in the cascade data module contains additional information
relative to operating modes.
D6 nnBaWahl
This data word is written to by the KETTE200 module.
D6.0 Manual mode H
D6.1 Inching mode T
D6.2 Automatic mode
A
D6.3 Start s
D6.4 S + 1
D6.5 Set Step
D6.6 Fault acknowledgement
D6.7 Reset
r
D7.0 Halt h
D7.1
D7.2
D7.3
D7.4
D7.5
D7.6 WSB does not reset BEFA (Manual mode only)
1
D7.7 Fault requires acknowledgement
Fig. 3-6 D6 — Selected Operating Mode
D6.0 Manual Mode
Define Manual mode.
D6.1 Inching Mode
Define Inching mode.
D6.2 Automatic Mode
Define Automatic mode.
D6.3 Start
Start / Command output enable
The bit is valid for all operating modes, and is statically transferred to D6.
If Start = 0
bin
, the following will occur:
• BEFA is deleted
• monitoring time is halted
• wait time continues to elapse
1
This option applies to the CL200 with firmware version 1.5 and higher.