Instruction manual
1070 072 163-101 (97.11) GB
CL200 Control Functions3-6
3.3.5 Messages
The messages from the KETTE200 module are returned via the
DM254/D510 data word.
The messages comprise error messages that cannot be entered in data
word D0. The status word has the following meaning:
Bit Error and/or Status message Remedy
15 Group error indication This bit always occurs in conjunction with one or more of
the bits listed below.
14
13 DM120 link is too short Correct the length of the data module.
12
11
10
9 Number of cascades from P3 = 0
dec
Enter desired number of cascade sequences.
8 Wrong cascade number for manual diagnosis. Correct default; program/integrate PMn and/or DMn.
7 Step module (PMn) not programmed. Program PMn module or remove associated DMn.
6 DMn link is too short Correct length of data module.
The cascade data modules must be integrated with a
length of
≥ 82 bytes.
As deliberate gaps in data module sequences allow the
formation of functional cascade groups, non-existing data
modules will not cause an error to be entered.
5 Cascade number, bit 5 If bit 6 is set, bits 0 thru 5 indicate the
4 Cascade number, bit 4 last cascade number in which the error
3 Cascade number, bit 3 was detected.
2 Cascade number, bit 2
1 Cascade number, bit 1
0 Cascade number, bit 0
Fig. 3-5 Status Message from KETTE200 in DB254/D510
NOTE: If the DM120 data module was not integrated into the program, the
controller will enter the STOP Mode while returning the Unknown
Module Called message.