Fault messages (cont'd.)
Code Subcode
dec
Subcode
hex
Fault description
3 1 1 Addressed module is not available.
3 16 10 Module does not respond.
3 35 23 Access to this address field is prohibited.
3 36 24 Access to this address field is protected by the user.
3 37 25 Timer may not be written to.
3 38 26 Module number too high.
3 39 27 Module not available.
3 40 28 Module too small.
4 32 20 Addressed data type (command code) unknown in PST.
4 33 21 Protocol ID is unknown to the peripheral station (PST).
4 35 23 Addressed coordination marker unknown in PST.
4 37 25 Parameter ID in message does not match specified parameters.
4 38 26 Difference between block length and actual data volume.
4 40 28 Unknown message type.
4 41 29 Unknown command type.
4 58 3A Start address does not match operand type (word on odd address).
4 59 3B Start address is outside of specified address range.
4 60 3C Invalid parameter for specified instruction.
4 61 3D Invalid operand type.
4 64 40 Peripheral station has not yet received identification message.
4 99 63 Specified data size is larger than addressed data range.
4 210 D2 Coordination marker is disabled.
Fig. 11-3 Fault Messages