Instruction manual

1070 072 163-101 (97.11) GB
Appendix 11-7
11.2.3 DIAG500E Diagnostics Module
Processing times, with-
out diagnostics module:
1 cascade, no fault,
no manual diagnostics.
0.5 ms
30 cascades, no fault,
no manual diagnostics.
1.4 ms
30 cascades, no fault,
manual diagnostics of 64
conditions.
2.1 ms
30 cascades, no fault,
manual diagnostics of 64
conditions.
5.0 ms
Number: Cascades max. 64
Steps max. 128 /Cascade
Step-on conditions max. 64 /Step