Instruction manual

1070 072 163-101 (97.11) GB
TS Programming System 9-33
9.4.5.5 BT20 – Display Mask No. 110
Insertions into the Display mask are restricted to fixed text sections and
variables (with text lists) describing specific tasks occurring in the course
of sequential controller processing.
File Edit Mask Editing Attribute
Normal
Reverse
Flashing
Underlined
Zoom
Fig. 9-56 Power-Up Conditions Mask Menu, Example BT20 Attributes
Pressing the [Alt-A] shortcut opens the Attribute menu, and the Normal
menu command is executed by pressing [RETURN].
Inserting text into mask
Using the cursor keys, the cursor is moved to the position indicated by the
intersection of Line5 / Column3. Using the keyboard, the text, e.g. Teil, is
typed directly into the mask. All text entries are listed in the table below.
Line Column Text
5 3Teil
5 8A
5 10 being
5 13 processed
7 3Teil
7 8B
7 10 being
7 13 processed
Fig. 9-57 Example of Text Entries in Display Mask, Example BT20
Example: Inserting E_TeilA variable into mask
The cursor is moved to the position indicated by the intersection of Line5
and Column25. In the Edit menu, the Variable menu command is se-
lected, and executed by pressing [RETURN].
File Edit Mask Editing Attribute
Variable
Edit textlist
Table description
Help text of variable
Recipe description
Position selection items
Edit selection items
Position messages
Message parameters
Fig. 9-58 Edit Variable Display Mask, Example BT20