TS Programming System 9-15
The following table lists all variables of the single-step controller in con-
junction with their respective assignments.
Line Col. Name of Variable Marker assigned in
standard
BTS-ZV parameter
4 3 I_C_1 M180.0 P2
4 11 O_C_1 M181.0 P3
4 31 O_V_1 M183.0 P11
4 39 I_V_1 M182.0 P10
7 3 I_C_2 M180.1 P4
7 11 O_C_2 M181.1 P5
7 31 O_V_2 M183.1 P13
7 39 I_V_2 M182.1 P12
10 3 I_C_3 M180.2 P6
10 11 O_C_3 M181.2 P7
10 31 O_V_3 M183.2 P15
10 39 I_V_3 M182.2 P14
13 3 I_C_4 M180.3 P8
13 11 O_C_4 M181.3 P9
13 31 O_V_4 M183.3 P17
13 39 I_V_4 M182.3 P16
Fig. 9-23 BT20 Parameters, Assignment of Variable Operation Masks
9.3.5.2 BT20 – Power-Up Conditions Mask
The description of one Power-up Conditions mask (here, M20-1) also ap-
plies to the remaining Power-up Conditions masks (2-4).
The Power-up Conditions mask can be used to display the various pre-
conditions existing for the start of the machine. A total of 4 masks is
available.
The contents of these masks are predefined only to the extent that the
short name of the mask, and the ZENTRALEINHEIT STEHT (ZE STOP)
and SYSREPOUTREPTEXTP (diagnostics message) variables are pro-
vided as default entries. These two variables are present in almost every
mask.
In the example used in the present section, two fixed texts and two vari-
ables are inserted into the Power-up Conditions mask.