TS Programming System9-8
The Zoom attribute comprises a special feature. It can be used to enlarge
a character to a size of max. four characters (i.e., a square of 2x2 size).
At this point, the enlarged character can be represented by placeholder
characters only. However, the character appears in its full size on the dis-
play of the operator terminal.
The Variables menu command of the Edit menu is used to insert vari-
ables. With this menu command selected, the Variables description
menu opens, displaying the menu bar shown below.
File Edit Editor
Select name
Select format
Select textlist
Edit textlist
Select graphical object
Select image list
Size of variable
Fig. 9-11 Variables Description Menu
File Edit Editor
Integer
Real
Floating point
Coded text
Alphanumerical
Hexadecimal
Binary
Timer
Counter
Password
Selection item
Curve
Beam
Coded image
BCD number
Fig. 9-12 Available Variables Format Menu
Pressing [F2] (or selecting the Select name command in the Edit menu)
displays the list of available variables for selection. A new variable is gen-
erated by entering a new variable name. In the event that, in the case of a
new and/or selected variable, the display format is missing, pressing [F4]
(or selecting the Select format command in the Edit menu) displays the
list of available formats. Selecting a format from this list causes it to be
adopted for the current variable.
The user also has the option to define a new format by typing a new name
in the Format name text box. The new format will adopt the settings dis-
played in this window. The extensive options for formatting variables are
described in more detail in the User Manual furnished by SÜTRON elec-
tronic GmbH.