Instruction manual
1070 072 163-101 (97.11) GB
BT20 Menu Description8-22
8.6.2 I /O /M /EI /EO Status / Control
Pressing the [F3] key in the Service menu displays the Status / Control
menu (mask numbers 60, 61, 70, 71, 80, 81, 90, 91).
The referred menus display the statuses of the PLC operands in the bi-
nary, hexadecimal, decimal and ASCII formats. Subsequent to being en-
abled, the displayed PLC operands can be controlled in DM255/D448 by
means of the BT operator terminal.
Status E/A/M/EZ/AZ aktiv: EZ
ZE STOP
By HEX. Dezim. HBy/LBy ASCII
200 4241 16961 066/065 >BA<
202 0000 00000 000/000 > <
204 0000 00000 000/000 > <
206 0000 00000 000/000 > <
208 0000 00000 000/000 > <
210 0000 00000 000/000 > <
212 0000 00000 000/000 > <
214 0000 00000 000/000 > <
120 0000 00000 000/000 > <
>Zeile für Z u s t a n d s m e l d u n g e n
E
→
A
→
M
T/Z
DF/DP
DBs
Fig. 8-21 I /O /M /EI /EO Status in Hexadecimal, Decimal <-> Byte decimal /Byte decimal and ASCII Formats
Status E/A/M/EZ/AZ aktiv: M
ZE STOP
By HBy binär LBy Hex. Dezim.
0 00000000 00000000 0000 00000
2 10000000 00000000 8000 32768
4 00000000 00000000 0000 00000
6 00000000 00000000 0000 00000
8 00000000 00000000 0000 00000
10 00000000 00000000 0000 00000
12 00000000 00000000 0000 00000
14 00000000 00000000 0000 00000
26 00000001 00000000 0100 00512
>Zeile für Z u s t a n d s m e l d u n g e n
E
→
A
→
M
T/Z
DF/DP
DBs
Fig. 8-22 I /O /M /EI /EO Status Menu in Binary, Hexadecimal <->, Hexadecimal, Decimal, and ASCII Formats