Instruction manual

1070 072 163-101 (97.11) GB
BT20 Menu Descriptions 8-19
8.5 Power-Up Conditions
Pressing the [F7] key in the Main menu displays the Power-Up conditions
(mask numbers 20 through 23).
The terminal display provides the user with 4 display masks.
Each mask allows the plain-text display of system-specific power-up con-
ditions in conjunction with their respective statuses by means of their im-
ages in the control operands.
Einschaltbedingunge
ZE STOP
Reparaturschalter ein
Automaten ein
Notstop
Schutzgitter auf
Endschalter
Erdschluß
Zeile für Z u s t a n d s m e l d u n g e n
 
Fig. 8-18 Example of Application-specific Power-Up Conditions
Using the TS (TesiMod) software, and under their respective mask num-
bers, the display masks must be completed with the required text and the
desired variables. The appropriate level / location is reached by using the
following sequence of menu commands:
Edit /Edit masks /Mask /Select mask /Number of mask.
It may also be necessary to enter a new variable description under Edit
masks /Variable. If new variables are to be used, these must also be de-
clared in the variables file under Edit /Variables file.
Display Contents
The display indicates current status messages (e.g. Outputs Disabled) via
the flashing LED in the [MELD] key. The messages appear in the display
line for status messages. Additional messages can be displayed in plain-
text form by pressing the [MELD] function key.
Menu Control
[CURSOR DOWN] Next group of four
[CURSOR UP] Previous group of four