Instruction manual
1070 072 163-101 (97.11) GB
BT20 Menu Description8-6
Operand Base Code
Inputs I 1000
Outputs O 3000
Markers M 4000
Special markers Sm 7000
Timers T 8000
Counters C 9000
Fig. 8-5 Operand Base Codes
Example: Input I0.2 (base code + byte address + bit address)
Base code 1000 = I0.0, base code 1001 = I0.1, etc.
Therefore, the following will apply:
For E0.2 = Zylinder2 fwd. -> Eingabe: 1002 = Zylinder2 backwd.
Display Contents
Cascade number and active step
OpMode:
• H Manual mode
• T Inching mode
• A Automatic
System date and time of first-value message occurrence
Number of criteria
Cascade status:
• F Cascade faulty!
Criteria status:
• Conditions not met
• Conditions met
Criteria text, up to 28 characters in length.
Menu Control
[F1] Page Down (displays next criteria)
[F2] Page Up (displays previous criteria)
[F3] Toggle: Manual and Automatic diagnostics
Manual diagnostics mode:
[F7] Cascade no. + 10 for cascade selection
[F8] Cascade no. + 1 for cascade selection
[F9] Cascade no. - 1 for cascade selection