Instruction manual

1070 072 163-101 (97.11) GB
BT5 Menu Description 7-21
7.5.3.1 Operand Status Display
S t a t . . E / A / M aktiv: A
2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
^ ^ ^ ^
Fig. 7-24 Example of Output Operand Status Display
Display Contents
The display indicates current status messages (e.g. Outputs Disabled) via
the flashing LED in the [?] key. The messages are displayed in plain text
by pressing the [SCROLL] key.
Menu Control
[F3] Operands, I -> O -> M -> (EI -> AI) -> I
[F4] Operands, Timers -> Counters
[F5] Operands, DF <-> (DB)
[F6] Operand, DM, display in decimal / hexadecimal
<-> byte decimal / ASCII
[CURSOR LEFT] or
[CURSOR RIGHT] Toggles display formats, I, O, M, DF, (DB), DM
[HOME] Operand status branching menu
[EDIT] Toggles Edit mode On/Off. With Edit mode en-
abled, editing is possible only in active mask.
The [HOME] key is disabled.
[1], [2], [3] ... Enter desired operand address.
[ENTER] Accepts/adopts entered operand address, or
transfers default of 0/1
bin
status to desired con-
troller mask.
CAUTION!
Pressing the [ENTER] key one more time will cause the control mask
to the written into the PLC!
Prerequisite:
The Control function is initially disabled. It is en-
abled by entering the value of 1
hex
in data word
D448 of data module DM255.