Instruction manual
1070 072 163-101 (97.11) GB
BT5 Menu Description 7-19
7.5.2 Power-Up Conditions
Pressing [F1] in the Service menu opens the Power-Up menu (mask
numbers 20 through 23).
In the display of the BT operator terminal, the user can access 4 display
masks.
Each mask comprises a matrix of 20 horizontal by 4 vertical characters.
The masks can be used, for example, for displaying application-specific
text messages, and/or the statuses of PLC operands.
Each mask allows the plain-text display of 4 system-specific power-up
conditions in conjunction with their respective statuses by means of their
images in the control operands.
Hy dr a u l i k 1 e i n
Hy dr a u l i k 2 e
i
in
Hy dr a u l i k 3 e
i
in
Hy dr a u l i k 4 e
i
in
Fig. 7-22 Example of Application-specific Power-Up Conditions
Using the TS (TesiMod) software, and under their respective mask num-
bers, the display masks must be completed with the required text and the
desired variables. The appropriate level / location is reached by using the
following sequence of menu commands:
Edit /Edit masks /Mask /Select mask /Number of mask.
It may also be necessary to enter a new variable description under Edit
masks /Variable. If new variables are to be used, these must also be de-
clared in the variables file under Edit /Variables file.
Display Contents
The display indicates current status messages (e.g. Outputs Disabled) via
the flashing LED in the [?] key. The messages are displayed in plain text
by pressing the [SCROLL] key.
Menu Control
[HOME Service menu
[CURSOR DOWN] Next group of four
[CURSOR UP] Previous group of four