Installation manual

SECTION 4 TESTING AND COMMISSIONING
The installation and programming should have been completed at this
stage.
1 Go into the Test Menu (Engineer Menu 8 or User Menu 3,4) or Keypad
F+3.
2 Activate the Security Check menu and do a walk test. Activate every
detector and ensure that the zone is announced on the Keypad.
Detectors will not cause alarms during this test. Press any key on the
Keypad to end this test mode. There is no time-out for Security
Check, so remember to turn it off using the # key. If a 24 hour zone
such as a tamper was active when exiting during Security check, it will
cause an alarm upon leaving Security Check.
3 Activate the Siren Test. The speaker and siren are activated for a few
seconds.
4 If a Strobe Light is connected, activate the Strobe Test. Ensure that the
strobe is switched on and off as directed.
5 Arm the security system to Away Mode. Check that the system arming
procedure is completed once the entry door is opened and closed. Any
programmed Away Mode response should be activated (eg turn off all
lights ‘A & B’)
6 Open the Entry Door. The Speaker and Keypad should give a slow
beeping tone, and any programmed Entry Alert Response should be
activated Light ‘A1’ switches ON. Entry path zones should be
announced but not cause an alarm. Sign in to disarm to Security Off -
code#. Program the telephone numbers for dialout, and activate the
dial test using Keypad F+3,3. The dial test is audible on the Keypad.
The dialled digits, busy and ringback tones, as well as pager tones,
Monitoring Station handshake and kiss-off tones are audible. Ensure
that the dial outs are successful. If a cellular phone is programmed,
check that it can sign in and access the system. Note that a Central
Station Kiss-off or a Voice phone sign-in will stop further dialouts to
the group of telephones which it is in, i.e. Phones 1,2 or 3 to 8, If the
system is unable to dial out successfully, see the next section on
troubleshooting.
7 Arm the system and trigger an alarm. Ensure that the siren and strobe
turns on, and that the system dials to the programmed numbers. When
the system dials to a Voice phone, check that the alarm voice menu is
heard, and do alarm history, alarm tracking, and disarm.
8 Disconnect the Tamper input. A tamper alarm should be generated. (24
hour alarm). Reconnect the tamper input and disarm to turn off the
alarm.
9 Activate the programmed home control menus to control the
programmed appliances using F2 or User Menu 4.
10 Record a memo using F+4. End the recording by pressing any key. The
Message LED should come on steady to show that there is a new memo
message. Sign in to hear the new message. If the message is
distorted, reduce the recording volume by adjusting the DSPKR
trimmer. Messages recorded on the Keypad will not be as clear as
recordings from the telephone, because of background noise.
Comfort Installation Manual
92