Installation manual
main system. The zones which are omitted can be programmed as
immediate in all modes to simulate an independent partition.
Reporting Bypassed Zones
Bypassed zones may be reported to the programmed phone numbers.
Alarm Type 16 is the Bypass Zone alarm. Set the dialout to ON and
program the combination of dial indexes 1 to 8 to report for this event.
When the system is auto-armed and Force arming is enabled, any
zones auto-bypassed can be reported to the programmed CMS,
telephones or pagers.
Playing a warning message on a Keypad or Door Station
When movement is detected in a zone, a warning message can be
played on any Keypad or Door Station. Record the warning message as
a Reminder message. The Time and days of week do not need to be
set, and the Reminder does not need to be turned on. Program the
Zone response of the movement detector for a Response using actions
133, reminder # (1-8), id. ID is 1 to 8 for keypads 1 to 8, or 49 to 51
for Door Stations 1 to 3. This will cause the reminder to be played on
the selected keypad or door station when the zone is triggered.
Response 116 by default plays Reminder 8 on keypad 1. See
Application Manual section 5.6 for more details.
Programming a Vibration/Shock Analyzer
Vibration, shock or inertial sensors tend to cause false alarms when
knocked accidentally. To program a z vibration sensor zone to cause an
alarm only when knocked a number of times within a short time
window, use Response 86 in the Zone Response. Response 86 by
default causes an alarm only when the zone is activated 3 times within
30 seconds. This can be combined with a warning message on a keypad
whenever the zone is knocked. See Application Manual 2.11 for full
details.
Programming a zone for Entry Delay in Night Mode
Program Response 54 into the Zone Response. This causes an Entry
Delay when the zone is triggered in Night Mode. For Entry Delay in Day
mode, use Response 53
Daylight Saving Clock Adjustment (DST)
Comfort has the ability to advance or retard its own clock to
synchronise with the majority of countries who use Daylight Saving
Time. It does this using Response 90 in Time Program 16. This
Response will advance and retard the clock 1 hour. Few countries use
the same system of ‘DST’ and so it is necessary to set the parameters
to your country requirements. In the UK each of the adjustments
happen on the last Sunday of the months March and October. The Time
Program is set to occur every Sunday at 2.00 am. The response
contains the two months that the adjustments are to take place and the
second parameter sets the direction the clock adjustments should go.
Comfort Installation Manual
90