Installation manual

SECTION 1 GENERAL INFORMATION
Specifications
Zones
w 8 fully programmable zones on Control Panel, expandable to 16 or 24
with Local Expansion Module (LEM) and 64 with Remote Expansion
Module (SEP02)
w Each zone configurable for 0 or 2 end-of-line resistors
w Up to 32 predefined Zone types to simplify zone configuration
w Surge/Over voltage protection for each zone
Power Supply
w 16.5 V 40VA Class II
w Minimum Standby Battery requirement: 12V, 7 AH sealed lead-acid
battery for 4 hour standby. (UL985: One 7 AH battery for 24 hour
standby with 200 mA auxiliary current, or two 7AH batteries for 24
hour standby with 400 mA auxiliary current). Reverse protection for
battery.
w 1.5 A regulated DC supply with Resettable Fuse protection
w Supervised for Mains failure and low battery
w CPU Dimensions: h= 350 mm, w= 362 mm, d= 90 mm, weight 5 kg
boxed.
Auxiliary Supply Outputs
w 12V unswitched supply
w 12V switched supply (automatically reset when disarmed)
w Note: Both switched and unswitched auxiliary supplies and 8 Outputs
have a combined continuous current limit of 1A. (500 mA for UL
applications)
Alarm Outputs
w Speaker Drive with 20 siren patterns
w Siren Output with programmable siren pulse patterns
w Strobe output (12v)
w Combined Alarm Output current of 1.5 A max (with battery)
System Supervision
w Low Battery
w Mains failure
w Telephone Line cut
w Individual Zone tamper (open-circuit or short-wiring) with 2 end of line
resistors
w Dedicated 24 hour Tamper input (used for cabinet and siren tamper)