Installation manual

Action 93 - Baby Monitor Mode
Usage: 93, id, 91,25
Puts selected Keypad id in monitor mode, ie with its microphone on.
Any other Keypad can listen to the selected Keypad, when the Function
Key is pressed. 91,25 causes the system to go to the Baby Monitor
mode
Action 94 - Keypad to Zone Linkage
Usage: 94, id
When assigned to a zone response, it links the selected Keypad to the
zone. when an alarm occurs, the assigned Keypad will be selected for
Voice Station (audio verification) by activation of the zone (audio
verification).
Action 99 - User Authorisation Setting
Usage: 99, auth, 91, menu
This action determines which combination of user authorisation settings
is allowed access to the function key if a code is required. It checks the
user code authorisation settings (Table 38) against the value of auth to
determine if the code entered is valid for the function key selected. For
example, only codes with Program Authorisation may be allowed to
access programming functions, e.g. Change Date/Time, Answering
Machine settings etc.
Action 133 - Play Reminder Message on Keypad
When a zone is triggered, one of the 8 user-recorded reminder
messages can be played on the selected Keypad. For example,
someone prowling in the garden can be warned "This property is
protected by Comfort, the Ultimate Security System. Please leave
within 10 seconds or..."
See Programming With Action Codes for a full list of Actions.
See the Worksheet for the default Keypad Function Key Responses
Door Station Programming
Location 1674 determines how many Door Station are installed in the
system. Enter valid values 0 or 1 and reset the system by pressing the
Reset button on the Comfort PCB. There is no other programming
required for Door Stations. When the Door Station button is pressed,
the Keypad will chime in Home, Night or Day Mode. In Away mode the
system will dial to the programmed number according to the settings in
Alarm Type 26. A Doorbell Response may be programmed in Location
1691, which may be used for switching cameras or other
supplementary actions.
Advanced Programming
Comfort Installation Manual
86