Installation manual

Table 34 - Other Location Changes
This table gives a list of Locations, some of which may not be
mentioned in the other tables. Take note of the following Locations in
particular:
v 720 = Battery Test Interval . The interval in hours between automatic
Battery Tests when the Battery Test Option (Eng Menu 8,1) is ON
v 721 = Battery Test Duration. The time in minutes for each battery test
when the AC is turned off, allowing the system to run on battery
v 1685 = ”Phone Ringer Response”. Whenever the phone rings Comfort
may activate a response (0 - 255) if entered in this location. i.e. Flash a
light or switch off a noisy appliance such as a vacuum cleaner via X10.
v 1689 = ”OFF” word. The word number to be announced when the
Announce Zone Response (59) is assigned to a Zone OFF Response.
The system announces (Zone name ) OFF. A value of 255 removes the
word.
v 1690 = Zone Auto-shunt count. This is the number of successive
activation's of any zone in alarm state which will automatically shunt or
disable the zone from causing any further alarms. The count is reset by
arming, disarming, and activation of any other zone. If this feature is
not required, set the Location to 0 or 255
v 1698 = Voice Menu Speed The Voice menu speed can be changed to
suit the customer. The normal speed is 0. Numbers 1 to 6 give faster
speeds with the higher numbers being faster. Numbers 250 to 255 give
slower speeds with the lower numbers slower. The pitch of the voice is
not altered by this command. Reset the system after changing this
value
Table 35 - Location 39 and 40 Flag Settings
Location 39 has 8 flags which control certain settings. Some of these
are available in the engineer or user menus.
Wait for Dial Tone is set in Location 39
Location 40 also has 8 flags which control certain settings. Some of
these may be available in the Engineer menu.
The flags available in Location 40 are Ignore Line Cut (add value of 2),
Disable Voice on Door Station, and LEM03 16 input 0 output (add value
of 32). Refer to the descriptions of each flag in the Worksheet
(( Ignore Line Cut should not be used for UL installations or for a
monitored system. It is only for Home Automation installations
where security is not a concern.
Reset after changing any setting in Location 39 or 40
Table 37 - User Timers
8 user Timers can be used to do general timing functions (16 user
times in Outside 4.97+ firmware). Action Codes 194 (Start Timer), 85
(Stop Timer), 86 (Check timer) handle timers.
Comfort Installation Manual
84