Installation manual

0 = Idle
1 = Trouble - for trouble conditions
2 = Alert - for alert or perimeter states
3 = Alarm - for full alarm
The alarm state defines the priority of the alarm.
2,80 to 3Alarm State
If the alarm type is Trouble state, whether the system may be
armed when the alarm type is still active. Setting this to off will
prevent the user from arming the system during this alarm.
This applies only for Trouble Alarms and has no effect for
alarms of other states.
2,7Yes/NoTrouble Arm
Determines if this alarm type is reported in the Event Log2,6Yes/NoEvent Log
RemarksMenuValueItem
Table 21 - Other Dialout Parameters
Dial Delay (seconds)
This is the common delay time in seconds which is applicable whenever
Alarm Types are set for Dial delay.
Siren Delay (minutes)
This is the global delay time in minutes applicable when Alarm types are
set for Siren delay. When the value is N, the actual delay time could
range from N-1 minutes to N minutes. This value is only applicable
where Siren Delay has been selected in the each particular Alarm Type.
Number of Redials
This sets the limit for the number of redials to each phone number if
the outcome is not successful, i.e. busy, no answer, or no
acknowledgment.
Redial Time (seconds)
This is the delay after an unsuccessful call before Comfort redials the
same number.
Table 22 - Siren Types
Comfort has 20 Siren Types or patterns to cater for different audible
indications. Each Alarm Type is assigned a Siren Type. Siren Type
settings are not available directly in Engineer Menu, they can be
changed using Locations, as given in the Worksheet. It is not necessary
to change Siren type settings unless there is a special requirement.
Table 23 - Sound Types
Each Siren Type is assigned a Sound Type, which determines the
frequency of the sound on the speaker (but not the 12V Siren), and the
cadence or on-off pattern. The Sound Type of each Siren Type can be
programmed in the Locations given in table 22. The list of available
Sound Types is in Table 23. It is not necessary to change the default
Sound Types
Comfort Installation Manual
78