Installation manual

To prevent the system from being re-armed after a Soak Test zone
failure, enter a Response containing action code ‘20’ into the Soak Test
alarm type to cause an Engineer Reset lock-out.
Table 12 - Phone Settings (Engineer Menu 4,1)
Up to 8 phone numbers may be assigned for dialout during alarms. The
phone numbers may be assigned as Monitoring Station (1st 2 numbers
only), Voice Phone (landline or cellular phone), numeric pager or Alarm
Voice Message.
Central Monitoring Station must be assigned to Phone 1. Any backup or
alternative Central Station must be assigned to Phone 2. If no
monitoring is required, all 8 Phone settings may be assigned to other
phone types.
Each Alarm Type can be programmed to dial to any combination of the
8 telephone numbers. To do this, go to the Alarm Types menu
(Engineer Menu 2).
Table 13 - Monitoring Station Settings
Phones 1 and 2 out of the 8 may be set as Phone Type 4, or Monitoring
Station. Monitoring Station Code (sub-menu 1) is the Account number,
which may be 3 to 4 digits.
Monitoring Station Type (sub-menu 2) means the Format. The list of
formats supported is in Table 14. Use Contact ID format if possible as
the Report and Restore Codes in all Alarm types are defaulted to this
format. Contact ID is able to provide more information in its reporting,
and being a DTMF format, is faster than traditional pulse type formats.
Phone Number (sub-menu 3) is for the phone number of the Central
Monitoring Station receiver.
If Phone Type 1 or 2 is set to Monitoring Station Type in Engineer
menu, the User Program Menu 4 will not be able to change it. The User
Program menu is not able to set Monitoring Station phone type in
Phones 1 and 2.
In Comfort, unlike most other alarm panels, the Report and Restore
codes are programmed for each Alarm type, not by Zone.
Table 15 - Entry/Exit Time (Engineer Menu 4,2)
Entry Time (4,2,0)
The Entry Time is the time given for the user to disarm the system after
opening the Entry Door when the system is armed (Away, Night, Day
mode). If no valid sign-in is entered after the Entry Time, the system
goes into Entry Warning Time, during which a local alarm sounds (only
the internal speaker gives a pulsed tone).
Exit Time (4,2,1)
The Exit time is the time given for the user to leave the home during
local arming to Away or Holiday Mode, provided all zones are closed. At
Comfort Installation Manual
75