Installation manual
29 - Instant Day /Away (N.C. Intruder Alarm)
Similar to Zone Type 22, except that it is inactive in Night Mode.
30 - Instant Night/Away (N.O. Intruder Alarm)
Similar to Zone Type 5, except that it is normally open. It is intended
for PIRs in interior zones.
31 Instant Perimeter Away (N.O. Intruder Alarm Type 1)
Similar to Zone Type 14 except the circuit is normally open, a full alarm
will be generated only when an alert zone, or immediate zone is
activated within the next 10 minutes. A perimeter circuit response may
be programmed to operate lighting sequences, camera switching, video
recording or voice announcements. The circuit operating sensitivity is
500ms.
Customising Zone Behaviour with Responses
Each zone can have an response assigned to it to alter its operation or
to change it’s function, such as changing a zone from an immediate
type to entry / exit in Night Mode or adding a chime, placing a double
knock filter or soak testing it. You can use the On or Off response of
any zone to perform a function, or you may need to change the zone
type, the possibilities are endless. Select your required response and
enter its number into the relevant zone that is to have the attribute
using Eng Menu 1, (zone number#), 5 . Refer to Table 33 for
Responses.
53 Entry Delay in Day Mode
Circuits with this On response will initiate the entry procedure when the
system is in Day Mode and respond as normal when in Away Mode.
54 Entry Delay in Night Mode
Circuits with this On response will initiate the entry procedure when the
system is in Night Mode and respond as normal when in Away Mode. It
is commonly used to change a Hall movement detector’s behaviour.
59 Announce Zone (Conditional on Home Control Alert Menu 6)
Circuits with this On Response will announce their zone name
description from the Keypads on the system during all security modes.
If this response is assigned to the Zone Off Response, the system will
announce (Zone Name) OFF when the zone is deactivated. The word
number for “OFF” (i.e. 229) should be programmed in Location 1689.
Alternatively, word number 70 (“Close”) may be more suitable.
75 Chime, conditional (long)
Circuits with this On response will cause a long two-tone ‘chime’ sound
at the Keypads and speakers . This may be disabled by the user in Alert
Menu 6 in Home Control. (Siren Type 15)
84 Chime, unconditional (short)
Comfort Installation Manual