Installation manual
20 - 24-Hr Tamper (N.C, Tamper Alarm)
A circuit that will generate a full tamper during all modes. System
cannot be armed when this zone type is active. Can be bypassed by
default, but bypass can be disabled by setting 24 Hr ON in Table 10
21 - Doorbell (N.O, Door Station)
The doorbell of an independent intercom system can be linked to the
Door Station by providing a normally open contact to a zone of this
type. This can activate the Door Station which is mounted next to the
intercom system so that the user can talk to the visitor at the door from
a mobile phone when the system is armed to Away.
22 - Water Sensor (N.O, 24hr Soak Test/Warning Alarm)
This zone type is intended for use with the WD2800 water sensor. This
24hr zone provides an audible alarm and dialout whenever a water leak
is detected.
23 - Fire (N.C, Fire Alarm Type 12)
A normally closed 24-Hr circuit which is usually connected to a smoke
or heat detector. When activated it will generate a fire alarm sound
from the speakers and pulse the 12v sirens for 10 minutes. A
programmed response may be triggered in the zone setting or fire
alarm type to switch lights on aiding an escape or to open an automatic
gate to enable easier access for the fire services. Cannot be bypassed.
24 - Switch (N.C. Null Alarm Type 0)
This zone type is the same as type 8 except the switch used should be
normally closed type circuit such as for security lighting applications.
25 - Vibration 20 ms (N.C. Intruder AlarmType 1)
Similar to Zone Type 7, except that sensitivity is 100 ms
26 - 24 Hour Zone (N.C. Intruder Alarm Type 1)
A circuit which will cause an Intruder Alarm in all modes
27 - 24-hour (N.O. Intruder Alarm Type 1)
A circuit which will cause an Intruder Alarm in all modes
28 - Line Fault 24-hour (N.C. Line Fault)
A normally closed circuit that will cause a local alarm when triggered
to alert the user of a line fault and will stamp the log and report
‘phone trouble’ in the voice menu. It is used as in input from
stand-alone communications equipment such as RedCARE or Paknet.
Comfort may signal this condition using it’s own Dialler provided
Alarm Type 4 is programmed for dial-out and the phone line is
intact. The option to prevent arming while this alarm is active is
selectable only through CS-Xpress Alarm Types. The user may
Bypass this zone using the Bypass Menu allowing arming. Always
name the zone as ‘Phone Tamper’ along with it’s zone number for
identification by the user.
Comfort Installation Manual