Installation manual
4 - Alert Away (NC, Alert)
This circuit is the same as zone type 3 except it is not active during
Night and Day Mode .
5 - Instant Night/Away (NC, Intruder Alarm)
A circuit that will generate a full alarm during Night and Away Modes
and not Day Mode. It is intended for PIRs in interior zones
6 - Alert Vibration Night/Away (NC, Alert Alarm)
This circuit is the same as zone type 3 except it has an operating
sensitivity of 50ms and is suitable for use with non-electronic
(mechanical) inertia shock detectors. A zone response may be needed
to act as an analyser.
7 - Instant Vibration Armed (NC, Intruder Alarm)
A circuit that has an operating sensitivity of 50ms which is suitable for
use with non-electronic (mechanical) inertia shock detectors and will
generate a full alarm in only Night and Away Modes.
8 - Switch (N.O. Null Alarm)
A normally open circuit which will not activate an alarm but can be used
to activate a response at all times. Responses may be applied to action
of closing, opening or both. The circuit operating sensitivity is 200ms
and is suitable for use with detectors with a negative applied trigger
output such as light sensors and some external movement detectors.
9 - Monitor (N.O, Alarm Type 14)
This is used to dial out to programmed phones whenever the zone is
triggered. It can be used to monitor machinery breakdown. It activates
Alarm Type 14, which must have the appropriate dialout settings. A
similar N.C zone type is Zone Type 17
10 - Fire (N.O. Fire Alarm)
A normally open 24-Hr circuit which is usually connected to a smoke or
heat detector. When activated it will generate a fire alarm sound from
the speakers and pulse the 12v sirens for 10 minutes. A programmed
response may be triggered in the zone setting or fire alarm type to
switch lights on aiding an escape or to open an automatic gate to
enable easier access for the fire services. Cannot be bypassed.
11 - Gas (N.C, Gas Alarm)
A 24-Hr circuit which will generate a gas alarm sound on the speakers
and operate the siren for 10 minutes. A programmed response may be
triggered in the zone setting or gas alarm type to switch the gas supply
‘OFF’ or open doors and windows. This zone type can be bypassed by
default, but bypass can be disabled by setting 24 Hour ON in Table 10
Comfort Installation Manual