Table 10 - Zone Types - Miscellaneous Settings
An Entry door zone type starts an entry delay if the door is open when
the system is armed. In the Final Door arming method, it also
terminates the exit time when it is closed during arming to Away mode.
Each Zone Type can be defined as Normally open or closed. Most
security sensors are Normally closed. Normally Open and Closed
contacts cannot share the same zone.
The sensitivity of the zone (i.e. the minimum time which the sensor
needs to be tripped before considering it a valid activation) is defined
by the Zone Type. The sensitivity setting is coded from 1 to 7 as in
Table 11.
(( For UL installations, zone sensitivity should be set at 500 ms.
minimum
Selecting a Zone Type
To select the zone type for the zone enter * Engineer Code then #. You
will hear ‘Engineer Menu’ . Press 1 for ‘zone settings’, select your Zone
number followed by #. Press 2, you will hear the current zone type for
that zone,. Enter the zone type number required from the following list
of zone types.
The term ‘Instant’ zone type is sometimes referred to as an immediate,
burglar, night or intruder zone by other panel manufacturers.
0 Not Used
A totally disabled circuit for Alarm triggering. It cannot be used to
activate responses
1 - Instant Day/Night/Away (NC, Intruder Alarm)
A circuit that will generate a full alarm during Day, Night and Away
Modes and not Security Off Mode. It is intended for PIRs in zones which
are required to be armed during Day Mode foremost.
2 - Entry Door (NC, Entry Alert)
This type of circuit must be the first detector triggered when entering
the protected area whilst the system is set. Once set, activation of the
circuit will start the entry timer. The function of this circuit is
determined by the type of Away Arming Method selected. If Final Door
arming is programmed, then the system will not complete arming until
the door is closed on the way out and all other protected circuits are
clear.
3 - Alert Night/Away (NC, Alert)
A circuit that can be used to dial-out silently if activated during Night,
Away Modes generating an Alert Alarm ‘type 6’. A full alarm will be
generated only when another alert zone, perimeter or immediate zone
is activated within the next 10 minutes. .