Installation manual

Table 2 - Status Indicator Output Assignments
This table gives the Locations in outputs (1 to 16) can be assigned to
indicate the system conditions, shown. Enter the Output number in the
locations given. For example, to indicate Phone Line Cut on output 4,
Program Location 1695 with 4.
Table 3 - Away Arming Method (Location 1692)
Comfort has 3 methods of arming to Away Mode, i.e. when no one is in
the premises. In Final Door Arming, the exit delay is terminated and the
system armed when the user exits via the designated Entry Door (Zone
Type 2). In Arm after Exit Delay, the system is armed when the Exit
time expires and all protected zones are closed. This is used when an
Entry Door contact is not available. Exit Terminator is used for the UK,
and arms only when an Exit Terminator button is pressed during exit.
Table 4 - Zone Settings (Engineer Menu 1)
This is the key item to be programmed. In security only installations,
this may be the only programming needed, other than phone numbers
for dial out.
For each zone in the system, enter the selected zone number and #
key. The system announces the programmed zone settings. Select the
sub-menus to program the following:
w 1 - Description, up to 4 words from the Wordlist. If less than 4 words
are needed, enter 255# to terminate. If no description is entered for a
zone, the Zone number is used as the default description
w 2 - The Zone Type, which defines the type of detector or input. This is
the only mandatory setting for a zone. Unused zones are set to Zone
Type 0
w 3 - The Entry path setting (on/off). A zone on the Entry path does not
cause an alarm when it is triggered after the Entry Door is opened
when the system is armed.
w 5 - The On Response (the optional Response or program which is
activated when the Zone goes on ). ON means open for a normally
closed zone type and closed for a normally open zone type.
w 6 - The Off Response (the optional Response or program which is
activated when the Zone goes off ). OFF means closed for a normally
closed zone type and open for a normally open zone type.
Zone Types
There are 32 Zone Types available in the system. Zone Types define
the characteristics of the Zone, what type of zone it is, how it is
activated and in which security mode it is active, and what alarm it
triggers if it is activated when it is active. Zone Types make it easy to
program the system.
The 3 Zone Types tables show the default settings and how to change
them using Locations. It is rarely necessary to change default Zone
Types settings, unless there is a special requirement which is not
catered for by the default values. It is necessary to Reset the panel
Comfort Installation Manual
66