Installation manual
When the reset is required, Comfort automatically enables Engineer
access so that the Engineer may sign-in without the user needing to
authorise the access. Additionally, the engineer may be called by the
system if the user presses the function ‘0’ command and Alarm Type 30
has been programmed by the Engineer with Telephone number 8 prior.
Exit Terminator / Door Station Button
The doorbell may also be used as a ‘push-to set ‘ switch to truncate the
exit timer during arming of the system to Away or Holiday Modes. To
enable this function select Exit Termination check flag in CS-Xpress
under General Configuration or set Location 1692 to a value of 2. If an
external Door Station is not required or if more than one means of exit
termination are required (e.g. radio remote switch), a zone may be
assigned as the exit terminator. This circuit has a dual function of a
doorbell action and a final setting switch. Operation of this zone type
during the exit procedure will truncate the exit timer provided that all
other protected zones are clear. Operation of this circuit during Away
Modes will cause a dial-out if programmed within alarm type 25 to do
so. Operation while the system is unset will cause the Keypads to
sound and the home phones to ring (if ringer unit is installed).
Note: Response 67 MUST be entered as the zone ‘ON’
response for the above functionality.
Bell Delay (Siren Delay)
Some systems may be required to have a bell delay stipulated by the
Police authorities. If this is the case Comfort can accommodate this by
setting the Bell Delay in minutes into location 51 and set the ‘siren
delay’ flag within the relevant the alarm types such as ‘Intruder’ or
‘Duress’ using Engineer Menu ‘2’ option ‘5’ or CS-Xpress ‘Alarm Types’.
Abort / Open and Close Signalling
Comfort systems may be programmed to send an abort signal to the
central station should the alarm be disarmed within 90 seconds of an
alarm activation and/ or signal that the system has just been armed or
disarmed. Abort(20) and System Set(19) and System Open(17) are
alarm types found in the alarm types in Engineer Menu 2. To enable
reporting simply set each one to dial-out to telephone numbers 1 and 2,
and refer to table 18. The signalling protocol used should be Contact ID.
Alternatively, outputs may be used to trigger an open and close signal
via a RedCARE STU or DualCom transmitter.
See previous Section entitled ‘Connection to RedCARE or DualCom’
Comfort Installation Manual
62