Installation manual
Troubleshooting CS-Xpress
Symptom Possible Cause
LED’s D9 and D10 are not flashing No power to the UCM or
Location 1672 set to '0'.
‘Timed Out Waiting for Reply’ This can indicate that the
comms port on the PC is set
incorrectly or the RS232 cable is not
connected or the wrong type.
Too Many Checksum Errors This could be caused by an incorrect
upgrade routine from an older version
of CSXpress. De-install the
old version and do a fresh install.
Only D10 Green Led is flashing KA-KB connection is reversed.
You can get the latest version of CS-Xpress3 from the Technical Area of
the web site: www.comfort.org.uk/technical/index_beta.html
Remote Signalling Requirements for Police Response (UK)
Comfort systems which are requiring a Police response will require
setting to comply with certain regulations. The Central Station
signalling can either make use of Comfort’s built-in Digital
Communicator or can use the outputs to trigger a stand alone
communicator such as a RedCARE STU DualCom or even both. If the
onboard digital communicator is used, Telephone numbers 1 and 2
should be used for dialling the Central Station (ARC). Ensure that a
(contact ID) zone list is sent to the ARC along with the desired
response to be taken for each alarm type. Zones such as exit
terminators and other non-signalling zones should not be sent.
We have produced a form for this purpose in the program
worksheet manual.
Engineer Reset
Action Code ‘20’ initiates an Engineer Reset’ requirement and can be
applied within any existing Alarm Type Response or as it’s own
Response 83 within the desired Alarm Type or within Intruder Macro
Response 25. The Alarm Company can decide what type of alarm
Condition will require an Engineer reset after activation, such as
Intruder Alarm (1), Tamper (11), Bell Tamper (22) or Panic (12) etc.
When a user tries to arm the system after such an event has occurred,
they will hear’ invalid, please call engineer for reset’.
Remote Reset of the system
Whenever the system requires an engineer reset, all the installer need
do is sign-in with the engineer code and while in Menu 1 press the star
key*, you will hear ‘Engineer Reset’. This can be done locally or
remotely by dialling-in from any tone telephone.
Comfort Installation Manual
61