Installation manual

SECTION 3 PROGRAMMING
Comfort Security System
Zone
Entry Path
Zone Type
(0-31)
OFF ResponseON Response
Away, Night, Day
Home Mode
Settings
Trouble Alarm
Type (0-31)
Alarm Type
(0-31)
Entry Door?
Normally open/
closed?
Sensitivity
(0-7)
24 Hr?
Siren Type
(0-19)
Strobe?
Alarm State
(Idle, Trouble,
Alert, Alarm)
Dial
Out?
Event
Log?
Trouble
State Arm
allowed?
Phone No 1
On/Off
Phone No 2
On/Off
Phone No 3
On/Off
Phone No 4
On/Off
Phone No 5
On/Off
Phone No 6
On/Off
Phone No 7
On/Off
Phone No 8
On/Off
Dial Indexes
Description
(4 words)
Siren
Delay?
Dial
Delay?
CMS
Report
Code
CMS
Restore
Code
Class Code
(Contact
ID)
Figure 3.1 - Zones, Zone Types, Alarm Types, Siren Types
The above table shows the key relationship between Zones, Zone
Types, Alarm Types and Siren Types. Each Zone has settings for
Description, Entry Path, Responses, and also belongs to a Zone Type,
which determines the basic behaviour of the zone, like whether it is
Normally Open or Normally Closed, if it is a 24 hour zone, if it is an
Entry Door etc., and its Alarm Type. The Alarm Type determines the
Comfort Installation Manual
56