Installation manual

Keypad / DoorStation ID Selection:
Set the headers SW1 according to the ID of the Keypad according to
the table
OpenOpenOpen8
ShortOpenOpen7
OpenShortOpen6
ShortShortOpen5
OpenOpenShort4
ShortOpenShort3
OpenShortShort2
ShortShortShort1
SW1 - ASW1 - BSW1- CID
If a Door Station is installed, then a maximum of 3 Keypads may be
installed using the Comfort PSU. The ringer module RGR02 may also be
fitted. This rings the phone for 30 seconds whenever the doorbell is
presssed during ‘occupied’ modes. Up to 8 Keypads may be installed in
a system and including a maximum of 3 Door Stations (After version
4.100). If additional Keypads are required (4-8), a supplementary
12VDC power supply rated at 1A DC with battery back-up must be
installed. The negative (com) of the Comfort CPU auxiliary 12V output
should be connected to the negative 0V of the PSU as a reference.
Keypad ID’s must be numbered consecutively, for example, if there are
2 Keypads they must be set to ID’s 1 and 2.
After termination of the wires and ID selection, close the Keypad by
hooking the front housing to the back housing along the top edge and
pushing the bottom of the front housing into the back housing.
Switch on power to the Comfort Panel. A short beep should be heard on
the Keypad followed by "Security Off". The appropriate indicator LEDs
should light up. Now, program the number of Keypads and Door
Stations in the next section.
Door Station as Intercom
The Door Station can be used as an intercom within the premises, by
making it appear as a Keypad. Set JP5 so that the Door Station is a
Keypad. Set the ID switches in SW1 to select the next available address
for a Keypad. Program Location 1675 to correspond to the number of
Keypads in the system. Reset the Comfort panel. Pressing the Doorbell
button will initiate the Intercom mode just like pressing the F + 8
function key. The Doorbell button also switches communications to talk
mode when communications is established. However, this intercom
cannot terminate the Intercom Mode, as there is no F key. Intercom
mode can be terminated by the other Keypad or can be left to time
out. For more natural conversation use the telephone to answer the
Door Station or Intercoms and to listen to Keypads use Menu 5.
(( If Ringer Module RGR02 is fitted with Door Station, ensure
that Location 40 (Table 35) is set to a value of ‘4’ if RGR01 is
fitted then Location 40 can be set to ‘0’.
Comfort Installation Manual
32