should be multiplied by the minimum time duration that is required
under the relevant standards. The Amp/hour battery size should be of a
higher capacity than the result of the calculation. It is always advisable
to install the highest capacity battery which can physically fit into the
enclosure (7A/hr).
E.g.: QC = 0.650 A (650 mA)
8 hours required stand by
QC x 8 = Battery Size A/hr (Min)
0.650 x 8 = 5.2 Amp-hour, Next available Battery size is 6
Amp-Hour
Factory Restart
Comfort does not have a factory restart setting. The configuration is
stored within U4 Non-volatile memory (NVM), so either this can be
replaced with a formatted U4 with default values or you can use
CS-Xpress to overwrite the current configuration with a default
template. You can write a default NVM using the UCM01 module’s copy
socket by inserting a master default NVM placing a spare 24LC65 IC in
the copy socket and pressing ‘Copy’ on the UCM01 local button. This
takes around 12 seconds to write.
Comfort Installation Manual
27