Installation manual

Dial Test (8,3)
When this menu is selected, the Voice Menu says..
Dial Test, Please hang up
After you hang up the phone, Comfort will immediately dial out to all
the programmed phones, pagers and monitoring stations. It will not
seize the telephone line immediately as this is an Idle state alarm. On
pagers, the Dial Test alarm type is displayed. On voice phones, "Dial
Test" is announced when the phone is answered. For Monitoring
Station receivers, the Test report code is sent.
For Phone 1 and 2, any Voice Phone Sign-in or CMS kiss-off will stop
the dial test to this group. For Phones 3 to 8, any Voice Phone sign-in
will stop the dial test to this group of phone numbers.
Siren Test (8,4)
Selecting this option activates a short Siren test.
Strobe Test (8,5)
Strobe Test,
Press 1 for ON, 0 for OFF
Press 1 to activate the strobe light, and 0 to switch it off after the test.
Engineer Test Mode (8,6) - use for keypad and doorphone tampers
Engineer Test Mode Option OFF
Press 1 for ON, 0 for OFF
In Engineer Test Mode, no alarm or trouble signals or dial outs will be
generated. This mode allows the Engineer to work on the system freely.
The Telephone Line Cut detection is still active in this mode. When the
system is armed, the Engineer Test Mode is automatically turned off, in
case the Engineer has forgotten to turn it off. It is particularly useful
when opening or restoring the tamper link (remove JP7) within the
doorphones and keypads.
When the Engineer Test Mode is switched off, the system automatically
goes into Security Check mode to prevent alarms caused by zone
faults, any faults are reported to allow you to rectify them.