Installation manual
Star Menu (7,4)
Press 1 for Location Menu
2 for System Reset
3 for System Control Number
This menu is for special configurations which are not available in the
other menus.
Locations (7,4,1)
Enter Location and # key
Enter the Location which has up to 4 digits and the # key. The
Locations Menu is used to program settings which are not available on
the Engineer Menu. The Worksheet will give information on the
Locations which may be changed and values to use.
For Example, Location 1692 sets the Away Arming Method. Enter
1692#
Location 1692
Code 0
Enter New Number and # Key
Value 0 in Location 1692 means Final Door Arming, i.e. system is
armed after the Final Door is closed. To change to Arming after Delay,
enter 1#
System Reset (7,4,2)
This causes the system to be reset. The programmed parameters and
recorded messages are not erased by system reset. Reset the system
after changing zone sensitivities using Locations, or using CS-XPress to
download zone settings.
System Control Number (7,4,3)
This menu gives the current software version e.g.
Airconditioner 4, 20
The first word denotes a particular configuration for different countries
or applications. The numbers following denote the version, in this
example 4.20
Comfort Installation Manual
129