Installation manual
Code OFF,
Press 1 for ON, 0 for OFF
Each Function key can be programmed to require a user sign in code or
not. If a sign-in code is required, the when the Function key is
activated, the user will be asked to sign in. If the code is valid, then the
programmed Response is activated. The user authorisation settings are
in effect here, for arming, security menu, and Home Control.
Event Log (5,1)
The Event Log will be announced over the phone in the format (Date),
(Time), (event). If any key other than 1,2,9,0 is pressed, the voice
menu will say:
“Press 1 for next , 2 for previous 0 for 1st, 9 for last, 3 for Next
day, 4 for Previous day # to end”
Pressing 1, 2, 9, 0, 3 or 4 during the event log announcement will
immediately interrupt the announcement and go to the specified event.
In this way, you can go quickly to the event of interest.
Duress Code entered by user adding or subtracting ‘2’ from their code, it
will be preceded by: (time ) mailbox no ? sign-in code OK.
N/ADuress Alarm
Doorbell pressed while system is armedN/ADoorbell
System dial-test selected.N/ADial Test
Dial-out failed (Busy, no answer, no acknowledgment, no sign-in)N/ADial Failure
SEP, Door Station or Keypad tamper activation, 33-35=SEP 1-3,
49-51=Door Station 1-3 and 65-68=Keypads/Intercoms1-4.
Restore33,49,65 Tamper
Alarm
The system is armed to Day ModeN/ADay Mode
Keypad 1-8 data failure. Prefix denotes ID 65=Keypad 1, 66=Keypad 2,
67=Keypad 3, 68=Keypad 4
65 Restore65 Communications
Failure
Door Station 1-4 Data Failure. Prefix denotes ID. 49=Door Station 1,
50=Door Station 2, 51=Door Station 3
49 Restore49 Communications
Failure
Remote Expansion Module 1-3 Data Failure. Prefix denotes identity.
Address 33=SEP 1, 34= SEP 2, 35= SEP 3
33 Restore33 Communications
Failure
Date or Time Changed using user or program code.N/AChange Time
A zone was bypassed either by a user or automatically using a
response.
Zone No.
Bypass Off
Zone ‘Name’ Bypassed
The battery was tested with AC ‘OFF’ and found to be less than 10.5V.RestoreBattery Warning
System armed to Away Mode - Full SetN/AAway Mode
System failed to arm, returned to Security Off Mode.N/AArm Failure
Dial-out acknowledged by recipient pressing # key.N/AAlarm Voice Message
OK
Alarm activation aborted within the ‘Abort Time’.N/AAlarm Erased
DescriptionRestoralVoice Event
Comfort Installation Manual
125