Force Arm Option ON
Press 1 for ON, 0 for OFF
Set the option to ON (1) to allow force-arming by the user (default ON).
The user force-arms the system by pressing # during Security Check.
The zone which is auto-bypassed in this manner reverts to protected
status if it is subsequently closed. If the Force Arm setting is OFF,
pressing the # key during Security Check causes the arming to be
cancelled.
If an Auto-arm response is activated and Force arming is enabled, the
system will force arm and automatically bypass any open zones.
Siren Reverse (4,3,3)
Siren Reverse Option OFF
Press 1 for ON, 0 for OFF
Press 1 for ON and 0 for OFF. If the setting is OFF (0), which is the
default, the Siren Output is turned on (i.e. 12 V applied between SRN-
and 12VF) to turn on the siren. If ON, the voltage to the siren is applied
when there is no alarm and cut off for alarm. This is used to drive
self-actuated sirens with a built-in backup battery. Default is OFF.
Normally, 12V is applied to the Siren Terminals (JP9) to activate it. For
Self-actuating sirens which sound when voltage is removed and are
silenced when voltage is applied, the Siren Reverse Option must be set
to ON
Control Station (4,4)
This menu is for programming the Keypad Function keys
Enter Control Key
Enter Key 0 to 9 or *
Response 0,
Enter Response number and # key
Enter the new response (0 to 127) to be assigned to the Function Key.
When the Function key is activated, F + Control key, the programmed
Response will be triggered. The Response can give a shortcut to a
commonly-used sub-menu. See Programming with Action Codes
(Action 91) for a list of sub-menus. Any Response can be assigned to
Keypad function keys. This means that the Keypad can be used to
perform any function in the system!
Comfort Installation Manual