Installation manual
protected zones not closed, and these open conditions are not cleared,
there is a time-out of 5 minutes to clear these zones after which the
Arm Failure alarm is generated.
(( For remote arming, it is not necessary to leave by the front
door in order to arm. The system will arm after a short delay if
all zones are closed.
(( For BS4737 installations, the Exit time may not exceed 120
seconds.
Entry Warning Time (4,2,2)
20 seconds, enter new number and # key
Enter new entry warning time and #, or just # to leave the value
unchanged.
The Entry Warning Time is the time in seconds after the Entry Time
has expired to allow for a valid sign-in before an Intruder Alarm is
generated. This feature reduces the incidence of false alarms generated
by users while disarming. If the Entry Warning Time is set to 0, an
Intruder Alarm will be generated immediately upon expiry of the Entry
Time, without any Entry Warning.
(( For BS4737 installations, the combined Entry Time plus Entry
Warning Time should not exceed 45 seconds.
Night Exit Time (4,2,3)
5 seconds, Enter new number and # key
The Night Exit Time is the time in seconds allowed for people to leave
the protected zones during Night Arming. During this delay time, the
system produces a slow beeping tone on the speaker. If zones are
open, a faster beeping tone is heard, as well as the names of the open
zones on the Voice Station or the telephone.
Enter new entry time in seconds and #, or just # to leave the value
unchanged.
Minimum value for Night Exit Time is 4 seconds.
Unlike arming to Away or Vacation mode, the user is not required to
leave the home
Security Options (4,3)
Press 1 for Force Arm Setting
3 for Siren Reverse
Force Arm Setting (4,3,1)
Comfort Installation Manual
123