Installation manual
e.g.
Off Response 23, enter new number and # key
Enter new OFF response number and #, or just # to leave the value
unchanged. Enter 0# if no response is required This response is
executed after the duration specified above has expired.
Security Mode Response (3,5)
A response may be specified to execute when changing to one of the
Security Modes (home, away, night, vacation). For example, when
arming to Away mode, all lights and appliances may be programmed to
turn off.
Press 0 for Security off
1 for Away Mode
2 for Night Mode
3 for Day Mode
Press 0 to 3 to select the appropriate mode. The voice menu will say
the current response number. e.g.
Response 34, enter Response number and # key
If no response is required, enter 0#. To leave the value unchanged,
enter just #.
Response (3,6)
Enter Response Number and # key
This menu allows you to change the Actions associated with any
Response number. There are 99 Responses in the Comfort System.
Most of these are assigned to default Actions, but may be changed
according to your requirements. Refer to the Worksheet for the list of
default Responses and Programming with Action Codes booklet for the
list of Action Codes. Responses can be used to perform tasks when
triggered by Zone activation, Time Programs, Vacation Programs, Alarm
Types or Home Control. Each Response consists a series of Actions. An
Action performs a single task, e.g. switching an output on or off,
sending an X10 code, or an infrared remote control code, arming or
disarming the system. An Action consists of 1 to 4 bytes. The 1st byte
is the Action number, and subsequent bytes are the parameters for the
Action.
Enter the Response number (1 to 99) and #.
Comfort Installation Manual
117