Installation manual
This refers to the Contact ID Class Code, which is a single digit number
from 0 to 9. This is sent with the Contact ID report to Central
Monitoring Station. It is ignored for other Central Station formats.
Alarm Response (2,2)
Response (0 to 99), Enter Response number and # key
An Alarm Response or program may be performed when the alarm is
activated. For example, a response may be assigned to Entry Alert
(alarm type 10) to turn on a light when the entry door is opened in
Away Mode. Enter 0# if no response is to be performed.
Description (2,3)
Intruder Alarm, Enter New number and # key
Each Alarm type has an Alarm Phrase which is reported to Voice Phone
and Alarm Voice Message Phone Types. The sentence number 0 to 254
is programmed here. refer to the Worksheet for a list of applicable
sentences.
Strobe (2,4)
Strobe ON,
Press 1 for ON, 0 for OFF
If the strobe is to be activated during this alarm, press 1 for ON, else
press 0 for OFF.
Siren Type (2,5)
Siren Type (0 to 20), Enter new number and # key
Each alarm type is associated with a Siren Type. Each siren type has
characteristics which determine whether the siren is activated and the
cadence (continuous or pulsed), the sound pattern on the speaker and
the duration of the siren activation. Refer to the table of Siren Types.
(( For UL installations, Siren Type 2 (Temporal 3) must be used
for Fire Alarm (Alarm Type 12). This is the default setting.
Siren Delay Off
Press 1 for ON, 0 for OFF
A Siren Delay may be selected for Each Alarm Type.
Comfort Installation Manual